T0A Power circuits, lightning and battery safety

Power circuits and hazards: hazardous voltages, fuses and circuit breakers, grounding, electrical code compliance; Lightning protection; Battery safety

Drill this topic (12 questions) Print flash cards

This group covers the electrical hazards in a ham shack: shock from household and high-voltage circuits, protective devices such as fuses and breakers, grounding, lightning protection, and the dangers of storage batteries. Most of it is common sense backed by a few firm rules.

How electricity hurts you

Current flowing through the body is what causes harm. It can heat tissue and cause burns, disrupt the electrical signals that run your nerves, heart and cells, and force muscles to contract so you cannot let go of the conductor. All of these effects are real, so treat any energized circuit with respect.

AC wiring colors and fusing

In the US, a three-wire 120 V AC cable uses black for the hot conductor, white for neutral, and green or bare copper for the equipment (safety) ground. Treat black as live.

Fuses and circuit breakers protect against overload. They must be placed in series with the hot conductor only, so the dangerous side of the circuit is opened. Never replace a fuse with a larger rating: a 20 A fuse in a 5 A circuit lets four times the design current flow, and wiring or equipment can overheat and start a fire before it blows. A fuse protects the weakest part of the circuit, not you from shock.

Shock-prevention habits

Lightning protection and grounding

A lightning arrester (surge protector) on a coax feed line should be mounted on a grounded panel where the feed lines enter the building. That diverts surge current to the outside ground system before it reaches your equipment. All external ground rods and earth connections should be bonded together with heavy wire or strap so they stay at the same potential during a strike or a fault.

Battery safety

A 12 V storage battery can deliver very high current when shorted. Touching both terminals with dry hands is not normally a shock hazard at 12 V, but a dropped tool or a short can cause severe burns, fire, or even an explosion. Rapid charging or discharging, especially of an unprotected battery, creates heat and gas, so overheating and out-gassing (often of flammable hydrogen) are the hazards. Remove rings and watches, and charge in a ventilated area.

Key facts to memorize

Memory hooks

“Black bites, white is the white flag, green is the grass”: black is hot, white is neutral, green is ground. “Series with the hot” keeps the fuse where the danger lives.

Questions in this group (12): answers shown
  1. T0A01

    Which of the following is a safety hazard of a 12-volt storage battery that lacks internal protection circuitry?

    • A. Touching both terminals with your hands can cause electrical shock
    • B. Shorting the terminals can cause burns, fire, or an explosion ✓ Correct answer
    • C. RF emissions from a nearby transmitter can cause the electrolyte to emit poison gas
    • D. All these choices are correct

    A battery can deliver enormous current into a short circuit, so a dropped wrench across the terminals can cause burns, fire, or a rupture. At 12 V, touching both terminals with dry hands is not a shock hazard, and RF does not make electrolyte release poison gas.

  2. T0A02

    What health hazard is posed by electrical current flowing through the body?

    • A. It may cause injury by heating body tissue
    • B. It may disrupt the electrical functions of cells
    • C. It may cause involuntary muscle contractions
    • D. All these choices are correct ✓ Correct answer

    Current through the body heats tissue, interferes with the tiny electrical signals cells and nerves rely on, and can force muscles to contract involuntarily so you cannot let go. All three effects are real hazards, so all the choices are correct.

  3. T0A03

    In the United States, what circuit does black wire insulation indicate in a three-wire 120 V AC cable?

    • A. Neutral
    • B. Hot ✓ Correct answer
    • C. Equipment ground
    • D. Negative

    In US residential wiring, black insulation marks a hot (ungrounded) conductor that carries line voltage. White is neutral and bare copper or green is the equipment ground. Treat black as live at all times.

  4. T0A04

    What is the purpose of a fuse in an electrical circuit?

    • A. To prevent power supply ripple from damaging a component
    • B. To remove power in case of an overload ✓ Correct answer
    • C. To limit current and prevent shocks
    • D. All these choices are correct

    A fuse contains an element that melts when current exceeds its rating, opening the circuit and removing power during an overload. It does not smooth ripple, and it does not by itself prevent shock; it protects wiring and equipment from overheating.

  5. T0A05

    Why should a 5-ampere fuse never be replaced with a 20-ampere fuse?

    • A. The larger fuse would be likely to blow because it is rated for higher current
    • B. The power supply ripple would greatly increase
    • C. Excessive current could cause a fire ✓ Correct answer
    • D. Voltage drop in the higher current fuse could result in excessively low voltage to the device

    A 20 A fuse lets four times the intended current flow before opening. Wiring or equipment designed for 5 A could overheat and start a fire without the fuse ever blowing. A fuse is chosen to protect the weakest part of the circuit.

  6. T0A06

    What is a good way to guard against electrical shock at your station?

    • A. Use three-wire cords and plugs for all AC powered equipment
    • B. Connect all AC powered station equipment to a common safety ground
    • C. Ensure all capacitors used for high-voltage DC are fully discharged before working inside equipment
    • D. All these choices are correct ✓ Correct answer

    Three-wire grounded cords, a common safety ground for all equipment, and discharging high-voltage capacitors before working inside gear each reduce shock risk. Each is a valid precaution, so all the choices are correct.

  7. T0A07

    Where should a lightning arrester be installed in a coaxial feed line?

    • A. At the output connector of a transceiver
    • B. At the antenna feed point
    • C. At the AC power service panel
    • D. On a grounded panel near where feed lines enter the building ✓ Correct answer

    A lightning arrester belongs on a grounded panel where feed lines enter the building, so surge energy is diverted to the station ground outside before it reaches equipment. Putting it at the radio or antenna defeats that purpose.

  8. T0A08

    Where should a fuse or circuit breaker be installed in a 120V AC power circuit?

    • A. In series with the hot conductor only ✓ Correct answer
    • B. In series with the hot and neutral conductors
    • C. In parallel with the hot conductor only
    • D. In parallel with the hot and neutral conductors

    A fuse or breaker goes in series with the hot conductor only, so it opens the path carrying the dangerous voltage. Fusing the neutral could leave equipment energized with the protection blown. Parallel placement would just short the circuit.

  9. T0A09

    What should be done to all external ground rods or earth connections?

    • A. Waterproof them with silicone caulk or electrical tape
    • B. Keep them as far apart as possible
    • C. Bond them together with heavy wire or conductive strap ✓ Correct answer
    • D. Tune them for resonance on the lowest frequency of operation

    Bonding all ground rods and earth connections together with heavy wire or strap keeps them at the same potential during a lightning strike or fault, preventing dangerous voltage differences between equipment. Ground rods are not tuned or isolated.

  10. T0A10

    What hazard exists when rapidly charging or discharging an unprotected battery?

    • A. Overheating or out-gassing ✓ Correct answer
    • B. Excess output ripple
    • C. Electric shock
    • D. Overvoltage

    Charging or discharging a battery too fast creates heat and gas inside the cell, so it can overheat or out-gas flammable hydrogen and corrosive vapors. Ripple, shock and overvoltage are not the main hazards of rapid charge or discharge.

  11. T0A11

    What hazard exists in a power supply immediately after turning it off?

    • A. Circulating currents in the dc filter
    • B. Leakage flux in the power transformer
    • C. Voltage transients from kickback diodes
    • D. Charge stored in filter capacitors ✓ Correct answer

    Filter capacitors in a power supply can hold a dangerous charge long after power is removed. Discharge them, and verify with a meter, before touching anything inside. The other choices are not the main post-shutdown shock hazard.

  12. T0A12

    Which of the following precautions should be taken when measuring high voltages with a voltmeter?

    • A. Ensure that the voltmeter has very low impedance
    • B. Ensure that the voltmeter and its leads are rated for use at the voltages being measured ✓ Correct answer
    • C. Ensure that the circuit is grounded through the voltmeter
    • D. Ensure that the voltmeter is set to the correct frequency

    High-voltage measurements require a meter and test leads whose insulation and ratings exceed the voltage being measured; otherwise they can arc or fail. A low-impedance meter would load the circuit, and grounding a circuit through the meter or setting a frequency does nothing to protect you.